Commercial
Heavy Duty Water Softening System
with 2" High Molecular Weight (HM) Plastic Valve Models:
PA102, PA132, PA162, PA192, PA252, PA322
OPERATIONAL
FLOWS
MODEL
PA102
PA132
PA162
PA192
PA252
PA322
FLOW
RATE
PRESSURE
(PSI) LOSS (P)
10
GPM
1.5
2.0
2.5
1.0
1.0
1.0
20
GPM
3.5
4.5
5.0
2
2.5
3.0
30
GPM
6.0
7.5
9.0
4.0
4.5
5.0
40
GPM
9.0
11.0
13.0
6.5
7
7.5
50
GPM
12.5
15.5
18.0
9.0
9.5
10.5
60
GPM
-
20.0
23.0
12.0
12.5
14.0
70
GPM
-
-
29.0
15.0
16.0
18.0
80
GPM
-
-
-
19.0
20.0
22.0
90
GPM
-
-
-
-
24.0
26.0
100
GPM
-
-
-
-
-
-
110
GPM
-
-
-
-
-
-
120
GPM
-
-
-
-
-
-
The
above data was obtained from tests run by the University of Minnesota
St. Anthony Falls Engineering Lab. All specifications listed are
for a SINGLE unit operation.